Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 346
Filtrar
1.
Front Psychol ; 15: 1349329, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596334

RESUMO

The aim of this study was to explore the feasibility and preliminary effectiveness of a short-term, manualized schema therapy group for 77 patients with CBT-resistant mood and/or anxiety and/or personality disorders (PDs) in primary care. The primary focus was on the effects of this treatment on Early Maladaptive Schemas (EMS), schema modes, and psychological well-being. These aspects were assessed pre-and post-treatment treatment using the Young Schema Questionnaire (YSQ), the Schema Mode Inventory version 1.1 (SMI), and the Symptom Questionnaire-48 (SQ-48). The treatment consisted of 16 sessions, incorporating cognitive, behavioral, and experiential techniques. EMS significantly decreased from pre-treatment to post-treatment, as along with maladaptive schema modes. Adaptive modes increased, as did psychological wellbeing. There were no significant differences between the DSM-5 classifications regarding changes in the aforementioned measures, except for the maladaptive modes, where the value of the corrected within-subject effect indicated a significant interaction. Post hoc comparisons were therefore conducted which showed that patients with a mood disorder experienced more positive changes in maladaptive modes compared to patients with anxiety disorders and PDs (p < 0.001). There was no significant difference between those with PDs and those with Anxiety Disorders. Our findings provide preliminary evidence that short-term, manualized schema therapy might be an effective treatment for patients with CBT-resistant mood and/or anxiety and/or PDs in primary care.

2.
Eur J Appl Physiol ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551682

RESUMO

PURPOSE: The rising frequency of extreme heat events poses an escalating threat of heat-related illnesses and fatalities, placing an additional strain on global healthcare systems. Whether the risk of heat-related issues is sex specific, particularly among the elderly, remains uncertain. METHODS: 16 men and 15 women of similar age (69 ± 5 years) were exposed to an air temperature of 39.1 ± 0.3 °C and a relative humidity (RH) of 25.1 ± 1.9%, during 20 min of seated rest and at least 40 min of low-intensity (10 W) cycling exercise. RH was gradually increased by 2% every 5 min starting at minute 30. We measured sweat rate, heart rate, thermal sensation, and the rise in gastrointestinal temperature (Tgi) and skin temperature (Tsk). RESULTS: Tgi consistently increased from minute 30 to 60, with no significant difference between females and males (0.012 ± 0.004 °C/min vs. 0.011 ± 0.005 °C/min; p = 0.64). Similarly, Tsk increase did not differ between females and males (0.044 ± 0.007 °C/min vs. 0.038 ± 0.011 °C/min; p = 0.07). Females exhibited lower sweat rates than males (0.29 ± 0.06 vs. 0.45 ± 0.14 mg/m2/min; p < 0.001) in particular at relative humidities exceeding 30%. No sex differences in heart rate and thermal sensation were observed. CONCLUSION: Elderly females exhibit significantly lower sweat rates than their male counterparts during low-intensity exercise at ambient temperatures of 39 °C when humidity exceeds 30%. However, both elderly males and females demonstrate a comparable rise in core temperature, skin temperature, and mean body temperature, indicating similar health-related risks associated with heat exposure.

3.
Thromb Res ; 236: 4-13, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38377636

RESUMO

BACKGROUND: Guidelines advise 50 % and 25 % dose reduction of the therapeutic nadroparin dose (86 IU/kg) in patients with eGFR 15-29 and 30-60 ml/min respectively. For monitoring, peak anti-Xa levels are suggested. Data lack whether this results in therapeutic anti-Xa levels or in anti-Xa levels that are comparable to those of patients without renal impairment. AIMS: To determine dose ranges in patients with renal impairment that result in therapeutic anti-Xa levels and to determine the percentage of the 86 IU/kg dose that results in anti-Xa levels normally occurring in patients without renal impairment. METHODS: A retrospective cohort study was conducted in five hospitals. Patients ≥18 years of age, with an eGFR ≥ 15 ml/min were included. The first correctly sampled peak (i.e. 3-5 h after ≥ third administration, regardless of dose per patient) was included. Simulated prediction models were developed using multiple linear regression. RESULTS: 770 patients were included. eGFR and hospital affected the association between dose and anti-Xa level. The doses for peak anti-Xa levels of 0.75 IU/ml differed substantially between hospitals and ranged from 55 to 91, 65-359 and 68-168 IU/kg in eGFR 15-29, 30-60 and > 60 ml/min/1.73m2, respectively. In eGFR 15-29 and 30-60 ml/min/1.73m2, doses of 75 % and 91 % of 86 IU/kg respectively, were needed for anti-Xa levels normally occurring in patients with eGFR > 60 ml/min. CONCLUSION: We advise against anti-Xa based dose-adjustments as long as anti-Xa assays between laboratories are not harmonized and an anti-Xa target range is not validated. A better approach might be to target levels similar to eGFR > 60 ml/min/1.73m2, which are achieved by smaller dose reductions.


Assuntos
Nadroparina , Insuficiência Renal , Humanos , Redução da Medicação , Estudos Retrospectivos , Heparina de Baixo Peso Molecular/efeitos adversos , Insuficiência Renal/tratamento farmacológico , Testes de Coagulação Sanguínea , Anticoagulantes , Inibidores do Fator Xa
4.
J Emerg Med ; 66(3): e277-e283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38336570

RESUMO

BACKGROUND: There is concern that the values provided by devices using infrared thermometry in emergency departments (EDs) do not reflect body core temperature accurately. OBJECTIVES: Evaluation of three thermometers commonly used in the ED. METHODS: Two infrared ear thermometers and an infrared forehead thermometer were evaluated using 1) the Voltcraft IRS-350 calibration device, 2) comparing temperature values to a rectal end-exercise temperature (T-RECT) of 38.1°C in 12 participants, and 3) comparing temperature values to rectal temperature in 133 ED patients. RESULTS: Calibration across the human core temperature range revealed that the ear thermometers underestimated radiant temperature by 0.77 ± 0.39°C and 1.84 ± 0.26°C, respectively, whereas the forehead thermometer overestimated radiant temperature by 0.90 ± 0.51°C. After cycling exercise, all thermometers underestimated T-RECT (0.54 ± 0.27°C and 1.03 ± 0.48°C for the ear thermometers and 1.14 ± 0.38°C for the forehead thermometer). In the ED, the ear thermometers underestimated T-RECT by 0.31 ± 0.37°C and 0.46 ± 0.50°C, whereas the forehead thermometer exhibited a nonsignificant overestimation of 0.04 ± 0.46°C. If the threshold for fever in all systems had been set to 37.5°C instead of 38.0°C, the sensitivity and specificity of the systems for real fever (T-RECT ≥ 38°C) are, respectively, 71% and 96% (ear thermometer 1), 57% and 97% (ear thermometer 2), and 86% and 90% (forehead thermometer). CONCLUSION: We conclude that the investigated thermometers are not reliable as devices to measure radiant temperature, cannot be used to assess body core temperature during exercise, but may be used as a screening device, with 37.5°C as a threshold for fever in emergency care settings.


Assuntos
Temperatura Corporal , Febre , Humanos , Temperatura , Febre/diagnóstico , Termômetros , Sensibilidade e Especificidade , Serviço Hospitalar de Emergência
5.
Int Arch Occup Environ Health ; 97(1): 35-43, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37947815

RESUMO

PURPOSE: As climate change accelerates, healthcare workers (HCW) are expected to be more frequently exposed to heat at work. Heat stress can be exacerbated by physical activity and unfavorable working requirements, such as wearing personal protective equipment (PPE). Thus, understanding its potential negative effects on HCW´s health and working performance is becoming crucial. Using wearable sensors, this study investigated the physiological effects of heat stress due to HCW-related activities. METHODS: Eighteen participants performed four experimental sessions in a controlled climatic environment following a standardized protocol. The conditions were (a) 22 °C, (b) 22 °C and PPE, (c) 27 °C and (d) 27 °C and PPE. An ear sensor (body temperature, heart rate) and a skin sensor (skin temperature) were used to record the participants´ physiological parameters. RESULTS: Heat and PPE had a significant effect on the measured physiological parameters. When wearing PPE, the median participants' body temperature was 0.1 °C higher compared to not wearing PPE. At 27 °C, the median body temperature was 0.5 °C higher than at 22 °C. For median skin temperature, wearing PPE resulted in a 0.4 °C increase and higher temperatures in a 1.0 °C increase. An increase in median heart rate was also observed for PPE (+ 2/min) and heat (+ 3/min). CONCLUSION: Long-term health and productivity risks can be further aggravated by the predicted temperature rise due to climate change. Further physiological studies with a well-designed intervention are needed to strengthen the evidence for developing comprehensive policies to protect workers in the healthcare sector.


Assuntos
Transtornos de Estresse por Calor , Dispositivos Eletrônicos Vestíveis , Humanos , Equipamento de Proteção Individual , Temperatura Cutânea , Temperatura , Pessoal de Saúde , Transtornos de Estresse por Calor/prevenção & controle
6.
Eur J Appl Physiol ; 124(3): 775-781, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37864008

RESUMO

A common practice for those operating in cold environments includes repetitive glove doffing and donning to perform specific tasks, which creates a repetitive cycle of hand cooling and rewarming. This study aimed to determine the influence of intraday repeated hand cooling on cold-induced vasodilation (CIVD), sympathetic activation, and finger/hand temperature recovery. Eight males and two females (mean ± SD age: 28 ± 5 year; height: 181 ± 9 cm; weight: 79.9 ± 10.4 kg) performed two 30-min hand immersions in cold (4.3 ± 0.92 °C) water in an indoor environment (18 °C). Both immersions (Imm1; Imm2) were performed on the same day and both allowed for a 10-min recovery. CIVD components were calculated for each finger (index, middle, ring) during each immersion. CIVD onset time (index, p = 0.546; middle, p = 0.727; ring, p = 0.873), minimum finger temperature (index, p = 0.634; middle, p = 0.493; ring, p = 0.575), and mean finger temperature (index, p = 0.986; middle, p = 0.953; ring, p = 0.637) were all similar between immersions. Recovery rates generally demonstrated similar responses as well. Findings suggest that two sequential CIVD tests analyzing the effect of prior cold exposure of the hand does not impair the CIVD response or recovery. Such findings appear promising for those venturing into cold environments where hands are likely to be repeatedly exposed to cold temperatures.


Assuntos
Temperatura Baixa , Imersão , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Vasodilatação/fisiologia , Temperatura Cutânea , Mãos , Dedos/fisiologia
7.
Clin Chim Acta ; 553: 117689, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38052384

RESUMO

BACKGROUND: Vancomycin is a widely used antibiotic for the treatment of gram-positive bacterial infections, especially for methicillin-resistant Staphylococcus aureus (MRSA) infections. Due to a small therapeutic range and large inter-patient variability, therapeutic drug monitoring (TDM) of vancomycin is required to minimize toxicity and maximize treatment efficacy. Venous blood sampling is mostly applied for TDM of vancomycin, although this widely used sampling method is more invasive compared to less painful alternatives, such as the dried blood spot (DBS) method, which can be performed at home. METHOD: We developed an UPLC-MS/MS method for the quantification of vancomycin and creatinine in DBS. A fast sample preparation and short analysis run time of 5.2 min were applied, which makes this method highly suitable for clinical settings. Validation was performed according to international (FDA and EMA) guidelines. RESULTS: The validated concentration range was found linear for creatinine from 41.8 µmol/L to 722 µmol/L and for vancomycin from 3.8 mg/L to 76.6 mg/L (r2 > 0.990) and the inaccuracies, imprecisions, hematocrit effects, and recoveries were < 15 % for both compounds. No significant carryover effect was observed. CONCLUSION: Hence, we successfully validated a quantification method for the simultaneous determination of creatinine and vancomycin in DBS.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Vancomicina , Humanos , Cromatografia Líquida/métodos , Creatinina , Espectrometria de Massas em Tandem/métodos , Teste em Amostras de Sangue Seco/métodos , Reprodutibilidade dos Testes , Monitoramento de Medicamentos/métodos , Cromatografia Líquida de Alta Pressão/métodos
8.
Med Sci Sports Exerc ; 56(2): 382, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37793157
9.
J Dairy Sci ; 107(5): 2954-2967, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38101741

RESUMO

The use of veterinary drugs is of similar importance to that of human drugs in addressing health challenges. In this context, pharmaceuticals and their metabolites inevitably enter soil and water in unknown quantities. Therefore, this study collects and analyzes drug data from 2020 for 50 dairy farms located in Germany. The most frequently used substance group is antibiotics (40.13%), followed by antiphlogistics (18.86%), antiparasitics (13.09%), and hormones (9.29%). Treatment frequencies record the number of days per year on which an average animal on a farm was treated with a substance. The calculated values range from 0.94 to 21.69 d/yr and are distributed heterogeneously across farms. In this study, on average, a cow was treated on 6 d in 2020: 2.34 d with antibiotics, 1.07 d with antiphlogistics, 0.76 d with antiparasitics, and 0.41 d with hormones. In addition to individual farm management practices, other factors are related to treatment frequency. Farms with a veterinary care contract used more hormonal substances than farms without a care contract. In addition, higher milk yield coincides with more frequent treatments with antiphlogistic or hormonal substances. Other related factors include grazing, longevity, farm size, and use of a claw bath. Our study represents an important first step in describing the amounts and determinants of veterinary drugs used in livestock farming. Such insights on magnitudes and farm parameters are essential to estimate potential environmental effects and derive strategies to reduce veterinary drug use.


Assuntos
Drogas Veterinárias , Bovinos , Animais , Feminino , Humanos , Fazendas , Drogas Veterinárias/metabolismo , Indústria de Laticínios , Leite/metabolismo , Antibacterianos/metabolismo , Antiparasitários/metabolismo , Hormônios/metabolismo
10.
Ther Adv Infect Dis ; 10: 20499361231214901, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38127471

RESUMO

Background: Outpatient Parenteral Antimicrobial Therapy (OPAT) is considered a patient-friendly and cost-effective practice. Patients in the OPAT service can be at risk for developing adverse events. Due to extensive variations in practice, guidelines have been developed to minimize the risks. Objectives: In this first worldwide survey on OPAT, we explored the current OPAT services around the world, adherence to recommendations and identified best practices and challenges from different perspectives. Methods: An e-survey was conducted and consisted of questions about demographics, characteristics of the OPAT service, role of pharmacy, future developments, and respondents' views on improvements as well as best practices. Results: A total of 126 responses from 28 countries were included. Seventy-eight percent (78%) of the respondents stated that their facility provides antimicrobial therapy in the outpatient setting, whereas 22% did not. Forty-two percent (42%) of the hospitals with OPAT services had a specialized OPAT service, while 14% lacked specialized services and 22% had a partially specialized team in place. In facilities with a specialized OPAT service, the number of mandatory infectious disease (ID) consultations before discharge and clinical monitoring by an ID specialist or OPAT team member, the frequency of monitoring, and the availability of an OPAT registry were higher. A multidisciplinary team's presence was commonly noted as best practices. On the other hand, respondents experienced difficulties with reimbursement and lack of standardization in the screening, follow-up and monitoring of patients. Conclusion: This survey provides a better understanding of the implementation and practices of OPAT services globally and describes best practices and the challenges from different professionals.


Background: Outpatient parenteral antimicrobial therapy (OPAT) is defined as 'the administration of parenteral antimicrobial therapy in at least 2 doses on different days without intervening hospitalization'National and continental studies show a great proportion of unregulated OPAT services with the implementation of a specialized OPAT team varying extensively.Besides the perspectives of infectious disease specialists, the perspectives of other healthcare workers involved with OPAT is under investigated. Method: An electronic e-survey was conducted with questions about demographics, characteristics of OPAT service, the role of the pharmacy in OPAT, future developments and best-practices and challenges. Results: OPAT services have a high global adoption rate of 78%, however only 42% of healthcare facilities offer formal OPAT servicesFacilities with formal OPAT services have higher requirements for infectious disease consultation before discharge, clinical monitoring by an OPAT team member, monitoring frequency, and availability of an OPAT registryBest practices include a multidisciplinary OPAT team and the use of elastomer pumpsCommon challenges in OPAT involve reimbursement issues and lack of standardization in patient screening, follow-up, and monitoring. Conclusion: This is the first worldwide study exploring the implementation of OPAT services and perspectives of different professionals.


Best practices, implementation and challenges of outpatient parenteral antimicrobial therapy: results of a worldwide survey among healthcare providers.

11.
Neuropsychiatr Dis Treat ; 19: 2039-2054, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790802

RESUMO

Objective: Studies have reported inconsistent results regarding the extent to which neurocognitive recovery occurs in abstinent patients with alcohol use disorder (AUD). In addition to abstinence, other factors may have influenced this process and contributed to the inconsistencies. This review examines the factors investigated in this regard and describes the possible influence of each factor based on the evidence collected. Methodology: PubMed was systematically searched for articles published between January 2000 and July 2023. Longitudinal humane studies investigating neurocognitive recovery in abstinent adult AUD patients were included. Studies with a cross-sectional design were excluded, as were studies that did not classify AUD according to the DSM-IV or 5 criteria, only examined binge use, did not report neuropsychological outcomes or duration of abstinence, or where neurological disorders were present. Results: Sixteen categories of factors were distinguished from 31 full-text articles. Consistent patterns were found, indicating an association between neurocognitive recovery and the "smoking" and 'brain volume" factors. Consistent patterns were also found indicating that there is no relationship with "quantities of alcohol used" and "education level." A similar consistent pattern was also found for "polysubstance use", "gender" and "verbal reading", but the number of studies is considered limited. The association with "age" is studied frequently but with inconsistent findings. The remaining eight factors were regarded as understudied. Conclusion: The clearest patterns emerging from the evidence are a predominantly negative influence of smoking on neurocognitive recovery, associations between changes in brain area volume and neurocognitive recovery, and no association between neurocognitive recovery and the amount of alcohol consumed, as measured by self-report, nor with educational attainment. Future research on the understudied factors and factors with inconsistent evidence is needed, preferably through longitudinal designs with multiple assessment periods starting after at least two weeks of abstinence.

12.
J Anal Toxicol ; 47(9): 842-849, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37639616

RESUMO

Urine has been the preferred matrix for monitoring heroin and methadone adherence due to its large detection window. Drawbacks such as privacy concerns and adulteration however require other matrices. The study aims to determine if oral fluid and exhaled breath are suitable alternatives for heroin and methadone monitoring and to assess the detection time in exhaled breath. Forty-three participants, all on methadone and heroin-assisted treatment, were studied. Participants were monitored after the first and right before the second dosage of heroin. At both time points, oral fluid and exhaled breath samples were collected with urine at the second time point. All samples were screened for opiates, methadone and other drugs using immunoassay and LC-MS-MS. At the second time point, 98% of oral fluid samples and all exhaled breath samples tested positive for 6-monoacetylmorphine (6-MAM). Regarding morphine detection, the findings were reversed (100% in oral fluid, 98% in exhaled breath). Methadone-related results were 100% positive across all matrices, as expected. Notable is the detection of the heroin marker acetylcodeine in oral fluid and exhaled breath samples, which resulted in relatively low negative predictive value (average 54.6%). Oral fluid and exhaled breath are suitable alternatives for heroin and methadone maintenance monitoring. Clinicians should consider ease of collection, adulteration risk, costs, turn-around time and the substance of interest while choosing a matrix. In addition, even in cases when medicinal heroin is used, medical professionals should be aware of the presence of acetylcodeine in these alternate matrices.


Assuntos
Dependência de Heroína , Heroína , Humanos , Detecção do Abuso de Substâncias/métodos , Metadona/uso terapêutico , Tratamento de Substituição de Opiáceos , Adesão à Medicação , Dependência de Heroína/diagnóstico , Dependência de Heroína/tratamento farmacológico
13.
Med Sci Sports Exerc ; 55(11): 2014-2024, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37418241

RESUMO

PURPOSE: For wheelchair users with a spinal cord injury, the lower body may be a more convenient cooling site than the upper body. However, it remains unknown if leg cooling reduces thermal strain in these individuals. We compared the impact of upper-body versus lower-body cooling on physiological and perceptual outcomes during submaximal arm-crank exercise under heat stress in individuals with paraplegia. METHODS: Twelve male participants with paraplegia (T4-L2, 50% complete lesion) performed a maximal exercise test in temperate conditions, and three heat stress tests (32°C, 40% relative humidity) in which they received upper-body cooling (COOL-UB), lower-body cooling (COOL-LB), or no cooling (CON) in a randomized counterbalanced order. Each heat stress test consisted of four exercise blocks of 15 min at 50% of peak power output, with 3 min of rest in between. Cooling was applied using water-perfused pads, with 14.8-m tubing in both COOL-UB and COOL-LB. RESULTS: Gastrointestinal temperature was 0.2°C (95% confidence interval (CI), 0.1°C to 0.3°C) lower during exercise in COOL-UB versus CON (37.5°C ± 0.4°C vs 37.7°C ± 0.3°C, P = 0.009), with no difference between COOL-LB and CON ( P = 1.0). Heart rate was lower in both COOL-UB (-7 bpm; 95% CI, -11 to -3 bpm; P = 0.01) and COOL-LB (-5 bpm; 95% CI, -9 to -1 bpm; P = 0.049) compared with CON. The skin temperature reduction at the cooled skin sites was larger in COOL-LB (-10.8°C ± 1.1°C) than in COOL-UB (-6.7°C ± 1.4°C, P < 0.001), which limited the cooling capacity in COOL-LB. Thermal sensation of the cooled skin sites was improved and overall thermal discomfort was lower in COOL-UB ( P = 0.01 and P = 0.04) but not in COOL-LB ( P = 0.17 and P = 0.59) compared with CON. CONCLUSIONS: Upper-body cooling more effectively reduced thermal strain than lower-body cooling in individuals with paraplegia, as it induced greater thermophysiological and perceptual benefits.


Assuntos
Regulação da Temperatura Corporal , Transtornos de Estresse por Calor , Humanos , Masculino , Regulação da Temperatura Corporal/fisiologia , Braço , Exercício Físico/fisiologia , Temperatura Cutânea , Paraplegia , Temperatura Alta , Temperatura Corporal/fisiologia
14.
Temperature (Austin) ; 10(2): 264-275, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332304

RESUMO

Paralympic athletes may be at increased risk for exertional heat illness (EHI) due to reduced thermoregulatory ability as a consequence of their impairment. This study investigated the occurrence of heat-stress related symptoms and EHI, and the use of heat mitigation strategies in Paralympic athletes, both in relation to the Tokyo 2020 Paralympic Games and previous events. Paralympic athletes competing in Tokyo 2020 were invited to complete an online survey five weeks prior to the Paralympics and up to eight weeks after the Games. 107 athletes (30 [24-38] years, 52% female, 20 nationalities, 21 sports) completed the survey. 57% of respondents had previously experienced heat-stress related symptoms, while 9% had been medically diagnosed with EHI. In Tokyo, 21% experienced at least one heat-stress related symptom, while none reported an EHI. The most common symptom and EHI were, respectively, dizziness and dehydration. In preparation for Tokyo, 58% of respondents used a heat acclimation strategy, most commonly heat acclimatization, which was more than in preparation for previous events (45%; P = 0.007). Cooling strategies were used by 77% of athletes in Tokyo, compared to 66% during past events (P = 0.18). Cold towels and packs were used most commonly. Respondents reported no medically-diagnosed EHIs during the Tokyo 2020 Paralympic Games, despite the hot and humid conditions in the first seven days of competition. Heat acclimation and cooling strategies were used by the majority of athletes, with heat acclimation being adopted more often than for previous competitions.

15.
Med Sci Sports Exerc ; 55(10): 1835-1844, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37227231

RESUMO

PURPOSE: This study aimed to compare the impact of hot-humid environmental conditions on performance outcomes, thermoregulatory responses, and thermal perception during exercise between elite para- and able-bodied (AB) athletes. METHODS: Twenty elite para-athletes (para-cycling and wheelchair tennis) and 20 elite AB athletes (road cycling, mountain biking, beach volleyball) performed an incremental exercise test in a temperate environment (mean ± SD, 15.2°C ± 1.2°C; relative humidity, 54% ± 7%) and a hot-humid environment (31.9°C ± 1.6°C, 72% ± 5%). Exercise tests started with a 20-min warm-up at 70% of maximal heart rate, after which power output increased by 5% every 3 min until volitional exhaustion. RESULTS: Time to exhaustion was shorter in hot-humid versus temperate conditions, with equal performance loss for para- and AB athletes (median (interquartile range), 26% (20%-31%) vs 27% (19%-32%); P = 0.80). AB athletes demonstrated larger exercise-induced increases in gastrointestinal temperature (T gi ) in hot-humid versus temperate conditions (2.2 ± 0.7 vs 1.7 ± 0.5, P < 0.001), whereas T gi responses in para-athletes were similar between conditions (1.3 ± 0.6 vs 1.3 ± 0.4, P = 0.74). Para- and AB athletes showed similar elevations in peak skin temperature ( P = 0.94), heart rate ( P = 0.67), and thermal sensation score ( P = 0.64) in hot-humid versus temperate conditions. CONCLUSIONS: Elite para-athletes and AB athletes demonstrated similar performance decrements during exercise in hot-humid versus temperate conditions, whereas T gi elevations were markedly lower in para-athletes. We observed large interindividual variation within both groups, suggesting that in both para- and AB athletes, personalized heat mitigation plans should be developed based on individual thermal testing.


Assuntos
Temperatura Alta , Paratletas , Humanos , Exercício Físico/fisiologia , Regulação da Temperatura Corporal/fisiologia , Atletas , Umidade
16.
Eur J Appl Physiol ; 123(8): 1709-1726, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37005962

RESUMO

PURPOSE: This study examined physiological and perceptual parameters related to cold-induced vasodilation (CIVD) in the fingers and toes of people with paraplegia and compared them with responses observed in able-bodied individuals. METHODS: Seven participants with paraplegia and seven able-bodied individuals participated in a randomized matched-controlled study involving left-hand and -foot immersion in cold water (8 ± 1 °C) for 40 min during exposure to cool (16 ± 1 °C), thermoneutral (23 ± 1 °C), and hot (34 ± 1 °C) ambient conditions. RESULTS: Similar CIVD occurrence was observed in the fingers in the two groups. In toes, three of the seven participants with paraplegia revealed CIVDs: one in cool, two in thermoneutral, and three in hot conditions. No able-bodied participants revealed CIVDs in cool and thermoneutral conditions, while four revealed CIVDs in hot conditions. The toe CIVDs of paraplegic participants were counterintuitive in several respects: they were more frequent in cool and thermoneutral conditions (compared to the able-bodied participants), emerged in these conditions despite lower core and skin temperatures of these participants, and were evident only in cases of thoracic level lesions (instead of lesions at lower spinal levels). CONCLUSION: Our findings demonstrated considerable inter-individual variability in CIVD responses in both the paraplegic and able-bodied groups. While we observed vasodilatory responses in the toes of participants with paraplegia that technically fulfilled the criteria for CIVD, it is unlikely that they reflect the CIVD phenomenon observed in able-bodied individuals. Taken together, our findings favor the contribution of central over peripheral factors in relation to the origin and/or control of CIVD.


Assuntos
Hipotensão , Vasodilatação , Humanos , Vasodilatação/fisiologia , Dedos do Pé/fisiologia , Dedos/fisiologia , Temperatura Baixa , Temperatura Cutânea , Paraplegia
17.
J Therm Biol ; 112: 103480, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36796923

RESUMO

Heat flux systems are increasingly used to assess core body temperature. However, validation of multiple systems is scarce. Therefore, an experiment was performed in which three commercially available heat flux systems (3 M, Medisim and Core) were compared to rectal temperature (Tre). Five females and four males performed exercise in a climate chamber set at 18 °C/50% relative humidity until exhaustion. Exercise duration was 36.3 ± 5.6 min (mean ± standard deviation). Tre in rest was 37.2 ± 0.3 °C. Medisim's-values were lower than Tre (36.9 ± 0.4 °C, p < 0.05); 3 M (37.2 ± 0.1 °C) and Core's (37.4 ± 0.3 °C) did not differ from Tre. Maximal temperatures after exercise were 38.4 ± 0.2 °C (Tre), 38.0 ± 0.4 °C (3 M), 38.8 ± 0.3 °C (Medisim) and 38.6 ± 0.3 °C (Core); Medisim was significantly higher than Tre (p < 0.05). The temperature profiles of the heat flux systems during exercise differed to varying degree from the rectal profiles; the Medisim system showed a faster increase during exercise than Tre (0.48 ± 0.25 °C in 20 min, p < 0.05), the Core system tended to show a systematic overestimation during the entire exercise period and the 3 M system showed large errors at the end of exercise, likely due to sweat entering the sensor. Therefore, the interpretation of heat flux sensor values as core body temperature estimates should be done with care; more research is required to elucidate the physiological significance of the generated temperature values.


Assuntos
Regulação da Temperatura Corporal , Temperatura Corporal , Masculino , Feminino , Humanos , Regulação da Temperatura Corporal/fisiologia , Temperatura , Temperatura Alta , Exercício Físico/fisiologia
18.
J Vet Med Educ ; : e20220071, 2023 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-36724159

RESUMO

A global survey was developed to gain insight into the opinion of companion animal veterinarians about their undergraduate education and their access to continuing education on the following topics: client communication, animal welfare, surgical techniques, human-animal bond, dentistry, animal behavior, and zoonotic disease/epidemiology. In 2016, the survey was distributed via SurveyMonkey® in five languages to companion animal veterinarians around the world. A total of 1,167 respondents returned to the survey. The distribution of survey responses differed by geographic region (number of respondents in parentheses; where respondents work/have been trained): Europa (including the Russian Federation, 359/423), Asia (311/205), North America (77/89), South America (24/16), Africa (46/41), and Oceania (147/167). The results were strongly influenced by a large number of respondents (in parentheses) who graduated in the Russian Federation (180/162), Australia (133/154), Israel (136/82), the Netherlands (64/64), the United Kingdom of Great Britain and Northern Ireland (36/46), and the United States of America (46/44). On the basis of the responses, all topics were poorly covered or not taught, except for surgical techniques and zoonotic disease/epidemiology, which were covered adequately or well. However, there were country and geographic regional differences. This was also true for continuing education resources, which were-in addition to countries and geographic regions-also influenced by the educational topic. As already stated by Dhein and Menon in 2003, time away from the practice, travel distance, and expense may be reasons why companion animal veterinarians do not follow continuing education. Online continuing education could fill in the gap and is more time and cost-efficient.

19.
Sports Biomech ; 22(5): 675-688, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-31466511

RESUMO

The aim of the study was to investigate whether jerk cost (JC) can discriminate between swimming levels. Nine elite and nine non-elite swimmers swam a 50-m front-crawl sprint wearing a 3D accelerometer on their back between the inferior angles of the scapulae. Lap times and JC were calculated from the acceleration signal and compared between groups and between swimmers within a group. The elite swimmers swam significantly faster lap times than the non-elite swimmers (p < 0.001). They did so with significantly lower levels of JC compared to the non-elite swimmers (p = 0.005). Furthermore, a stepwise multiple linear regression showed JC accounted for 32.9% of the variation in lap time of the elite swimmers. These results indicate that it is possible to discriminate elite from non-elite swimmers using JC: elite swimmers swim with lower JCs than non-elite swimmers. Additionally, swimming at higher speed is associated with more accelerations and decelerations in both elite and non-elite swimmers, which is reflected by higher JCs and lower smoothness. In sum, JC provides an index of swimming technique that is easy to use in training practice.


Assuntos
Aceleração , Natação , Humanos , Fenômenos Biomecânicos , Modelos Lineares
20.
Front Vet Sci ; 9: 939534, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36483490

RESUMO

Measuring physiological parameters of stress in horses during groundwork, for example when involved in equine-assisted interventions, is important to gain insight into the stress levels of the horses. Heart rate and heart rate variability can be used as physiological indicators of stress in horses. Heart rate monitors could be easily incorporated into practice, as they are not expensive and easy to use. However, it is questionable whether heart rate monitors present accurate heart rate variability results in exercising horses, similar to electrocardiograms. The aim of this study was to determine the accuracy of heart rate monitors for the assessment of heart rate variability in horses during groundwork exercise. Simultaneous telemetric electrocardiograms (Televet) and heart rate monitor (Polar H10 transmitter and M430 receiver, Hylofit electrodes) recordings were performed on 28 horses (15 mares and 13 geldings). Results indicate that the heart rate monitor accurately determined heart rate and time-domain heart rate variability parameters when compared to electrocardiograms during both baseline and groundwork conditions. As expected, heart rate significantly increased and the heart rate variability significantly decreased during groundwork compared to baseline conditions. This indicates that the heart rate monitor can be used to accurately determine heart rate variability during groundwork.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA